| Manufacturer Data |
| Specifications |
Manufacturer |
Text |
|
| Specifications |
Manufacturer Website |
URL |
|
| Specifications |
Product Range |
Text |
|
| Specifications |
Product Model Number |
Text |
or code |
| Specifications |
CE Approval |
Text |
Yes, No or the four digit identification number of the notified body involved in the conformity assessment procedure. |
| Specifications |
Product Literature Webpage |
URL |
|
| Specifications |
Product Features |
Text |
|
| Application |
| Specifications |
Intended Market |
Text |
eg Residentail, Commercial |
| Specifications |
Application Environment |
Text |
|
| Specifications |
IP Rating |
Text |
|
| Specifications |
Vandal Resistant |
Y/N |
|
| Specifications |
Mounting Type |
Text |
|
| Specifications |
Standards |
Text |
|
| Specifications |
Certifying Bodies |
Text |
|
| Specifications |
Removable |
Y/N |
|
| Specifications |
Raise or Lower |
Y/N |
|
| Specifications |
Raise or Lower Drive |
Text |
|
| Specifications |
Raise or Lower Method |
Text |
|
| Specifications |
Passive Safe |
Y/N |
|
| Specifications |
Ram Resistant |
Y/N |
|
| Specifications |
PAS Standard |
Text |
|
| Specifications |
PAS Rating |
Text |
|
| Construction Data |
| Specifications |
Type |
Text |
This is a COBie field, other fields will be required in final PDTs. |
| Specifications |
Shape |
Text |
This is a COBie field, other fields will be required in final PDTs. |
| Specifications |
Body Material |
Text |
|
| Specifications |
Cap Material |
Text |
|
| Specifications |
Lens Material |
Text |
|
| Specifications |
Diffuser Material |
Text |
|
| Specifications |
Optical Controller Material |
Text |
|
| Specifications |
Lamp Holder Material |
Text |
|
| Specifications |
Fixings or Bracket Material |
Text |
|
| Specifications |
Body Finish |
Text |
|
| Specifications |
Cap Finish |
Text |
|
| Dimensional Data |
| Specifications |
Overall Length |
mm |
|
| Specifications |
Overall Width |
mm |
|
| Specifications |
Overall Height |
mm |
Including root height (if applicable) |
| Specifications |
Root Height |
mm |
Height for below ground fixed bollard. |
| Specifications |
Gross Weight |
kg |
Equates to Operating Weight |
| Specifications |
Shipping Weight |
kg |
|
| Specifications |
Access Clearance Top |
mm |
|
| Specifications |
Access Clearance Bottom |
mm |
|
| Specifications |
Access Clearance Left |
mm |
|
| Specifications |
Access Clearance Right |
mm |
|
| Specifications |
Access Clearance Front |
mm |
|
| Specifications |
Access Clearance Rear |
mm |
|
| Performance Data |
| Specifications |
Reference Standard |
Text |
|
| Light Source Data |
| Specifications |
Lamp or Light Source Type |
Text |
|
| Specifications |
Nominal Wattage |
Watts |
|
| Specifications |
Lamp International Type Code |
Text |
|
| Specifications |
Lamp Cap |
Text |
|
| Specifications |
Light Source Included |
Y/N |
|
| Specifications |
Design Lumens |
Lumen |
|
| Specifications |
Efficacy |
Lm/W |
|
| Specifications |
Colour Temperature |
K |
|
| Specifications |
Colour Rendering Index |
Number |
|
| Specifications |
Nominal Rated Life |
Hours |
|
| Specifications |
Voltage |
Volt |
|
| Specifications |
No of Lamps |
Number |
|
| Electrical Data (if required) |
| Specifications |
Control Gear Required |
Y/N |
|
| Specifications |
Control Gear Type |
Text |
|
| Specifications |
Number of Control Gear Units or Luminaires |
Number |
|
| Specifications |
Control Gear Location |
Text |
|
| Specifications |
Integral Fuse or Circuit Protection |
Y/N |
|
| Specifications |
Suitable for Dimming |
Y/N |
|
| Specifications |
Suitable Dimmer Type |
Text |
|
| Specifications |
Suitable for Motion Detector Control |
Y/N |
|
| Specifications |
Available with Integral Motion Detector Controls |
Y/N |
|
| Specifications |
Suitable for Photocell Control |
Y/N |
|
| Specifications |
Available with Integral Photocell Controls |
Y/N |
|
| Specifications |
Available with Integral Emergency Lighting Battery |
Y/N |
|
| Specifications |
Integral Battery Type |
Text |
|
| Specifications |
Duration of Integral Emergency Lighting |
Hour |
|
| Specifications |
Number of Poles |
Number |
|
| Specifications |
Earth Point Provided |
Y/N |
|
| Specifications |
Electrical Class CVLASS |
List |
Select 1,2 or 3 |
| Specifications |
Electricity Supply Voltage |
Volt |
|
| Specifications |
Electricity Supply Phases |
Number |
|
| Specifications |
Electrical Supply Frequency |
Hertz |
|
| Specifications |
Electrical Supply Current |
Amp |
|
| Specifications |
Electrical Supply Total Power |
Watt |
|
| Specifications |
Electrical Supply Power Factor |
Number |
|
| Specifications |
Output Voltage to Lamp or Light Source |
Volt |
|
| Specifications |
External Control Line Voltage |
Volt |
|
| Specifications |
UMSUG Code |
Number |
|
| Sustainability |
| Sustainable Material BREEAM etc |
Embodied Carbon |
kgCO2 |
University of Bath ICE Data if none other available |
| Sustainable Material BREEAM etc |
Life Cycle Analysis |
Number |
BREEAM |
| Sustainable Material BREEAM etc |
Location of Manufacturer |
GridRef |
Northing,Easting |
| Sustainable Material BREEAM etc |
Green Guide for Specification |
Text |
A - E |
| Sustainable Material BREEAM etc |
Environmental Product Declaration |
Text |
3rd Party Verification |
| Sustainable Material BREEAM etc |
Responsible Sourcing of Materials |
Text |
Endorsing body |
| Sustainable Material ETL |
Energy Technology List |
URL |
Hyperlink to ETL webpage for product |
| Sustainable Material LEED v.4 |
Responsible Extraction of Materials |
Text |
|
| Sustainable Material LEED v.4 |
Material Ingredient Reporting |
Text |
|
| Operations & Maintenance |
| Facilities/Asset Management |
Operations and Maintenance Manual |
URL |
Hyperlink to Manufacturer O&M Data |
| Facilities/Asset Management |
Daily |
Text |
Maintenance tasks or SFG2012 codes. |
| Facilities/Asset Management |
Weekly |
Text |
Maintenance tasks or SFG2012 codes. |
| Facilities/Asset Management |
Monthly |
Text |
Maintenance tasks or SFG2012 codes. |
| Facilities/Asset Management |
Quarterly |
Text |
Maintenance tasks or SFG2012 codes. |
| Facilities/Asset Management |
6 Monthly |
Text |
Maintenance tasks or SFG2012 codes. |
| Facilities/Asset Management |
Annually |
Text |
Maintenance tasks or SFG2012 codes. |
| Facilities/Asset Management |
Bespoke Timeframe |
Text |
Maintenance tasks or SFG2012 codes. |
| Facilities/Asset Management |
Maintenance Required 0 to 300hrs |
Text |
Maintenance tasks required during this time frame. |
| Facilities/Asset Management |
Maintenance Required 301 to 600hrs |
Text |
Maintenance tasks required during this time frame. |
| Facilities/Asset Management |
Maintenance Required 601 to 1000hrs |
Text |
Maintenance tasks required during this time frame. |
| Facilities/Asset Management |
Maintenance Required 1001 to 2000hrs |
Text |
Maintenance tasks required during this time frame. |
| Facilities/Asset Management |
Maintenance Required 2001 to 4000hrs |
Text |
Maintenance tasks required during this time frame. |
| Facilities/Asset Management |
Maintenance Required 4001 to 8000hrs |
Text |
Maintenance tasks required during this time frame. |
| Facilities/Asset Management |
Maintance Required 8001 to 12000hrs |
Text |
Maintenance tasks required during this time frame. |
| Facilities/Asset Management |
Service Life |
Years |
|
| Facilities/Asset Management |
Luminaire Maintenance Factor |
% |
|
| Facilities/Asset Management |
Overall Luminaire Efficacy |
Lm/W |
|
| Facilities/Asset Management |
Annual Burning Hours |
Text |
|
| Facilities/Asset Management |
Lamp Replacement Interval |
Months |
|
| Facilities/Asset Management |
Luminaire Cleaning Interval |
Months |
|
| Facilities/Asset Management |
Lamp Survival Factor |
Text |
|
| Facilities/Asset Management |
Expected Life |
Years |
|
| Facilities/Asset Management |
Warranty ID |
Text |
|
| Post Applied Finishes |
| Facilities/Asset Management |
Graffiti Resistance |
Text |
Post applied graffiti protection |
| Facilities/Asset Management |
DDA Requirements |
Text |
|