Detail for Bollard - Non-illuminated (draft), version v2.3, created 03/02/2017

Back to list

Information CategoryParameter NameUnitNotes
Manufacturer Data
Specifications Manufacturer Text
Specifications Manufacturer Website URL
Specifications Product Range Text
Specifications Product Model Number Text Or Code
Specifications CE Approval Text Number, Yes, No
Specifications Product Literature Webpage URL
Specifications Product Features Text Free text to describe product
Application
Specifications Intended Market Text eg Residential, Commercial
Specifications Application Environment Text
Specifications IP Rating Text
Specifications Vandal Resistant Y/N
Specifications Mounting Type Text
Specifications Standards Text
Specifications Certifying Bodies Text
Specifications Removable Y/N
Specifications Raise or Lower Y/N
Specifications Raise or Lower Drive Text
Specifications Raise or Lower Method Text
Specifications Passive Safe Y/N
Specifications Ram Resistant Y/N
Specifications PAS Standard Text
Specifications PAS Rating Text
Construction Data
Specifications Type Text This is a COBie field, other fields will be required in final PDTs.
Specifications Shape Text This is a COBie field, other fields will be required in final PDTs.
Specifications Body Material Text
Specifications Cap Material Text
Specifications Fixings or Bracket Material Text
Specifications Body Finish Text
Specifications Body Colour Text
Specifications Cap Finish Text
Dimensional Data
Specifications Overall Length mm
Specifications Overall Width mm
Specifications Overall Height mm Including root height (if applicable)
Specifications Body Diameter or Width mm
Specifications Root Height mm Height for below ground fixed bollard.
Specifications Operating Weight kg
Specifications Shipping Weight kg
Specifications Access Clearance Top mm
Specifications Access Clearance Bottom mm
Specifications Access Clearance Left mm
Specifications Access Clearance Right mm
Specifications Access Clearance Front mm
Specifications Access Clearance Rear mm
Performance Data
Specifications Reference Standard Text
Electrical Data (if required)
Specifications Incoming Supply Electrical Voltage Volts
Specifications Incoming Supply Phase Number 1,3
Specifications Incoming Supply Electrical Frequency Hertz 50,60
Specifications Motor Enclosure Rating Text IP numbers
Specifications Motor Type Text
Specifications Number of Poles Number 1,3
Specifications Motor Efficiency Class CEMEP Text
Specifications Starting Method Text DoL,StarDelta, Soft
Controls
Specifications BMS Links Y/N
Sustainable Material BREEAM etc
Sustainable Material BREEAM etc Embodied Carbon kgCO2 University of Bath ICE Data if none other available
Sustainable Material BREEAM etc Life Cycle Analysis Number BREEAM
Sustainable Material BREEAM etc Location of Manufacturer GridRef Northing,Easting
Sustainable Material BREEAM etc Green Guide for Specification Text A - E
Sustainable Material BREEAM etc Environmental Product Declaration Text 3rd Party Verification
Sustainable Material BREEAM etc Responsible Sourcing of Materials Text Endorsing body
Sustainable Material LEED v.4 Responsible Extraction of Materials Text TBA
Sustainable Material LEED v.4 Material Ingredient Reporting Text TBA
Operations & Maintenance
Facilities/Asset Management Operations and Maintenance Manual URL Hyperlink to Manufacturer O&M Data
Facilities/Asset Management Daily Text Maintenance tasks or SFG2012 codes.
Facilities/Asset Management Weekly Text Maintenance tasks or SFG2012 codes.
Facilities/Asset Management Monthly Text Maintenance tasks or SFG2012 codes.
Facilities/Asset Management Quarterly Text Maintenance tasks or SFG2012 codes.
Facilities/Asset Management 6 Monthly Text Maintenance tasks or SFG2012 codes.
Facilities/Asset Management Annually Text Maintenance tasks or SFG2012 codes.
Facilities/Asset Management Bespoke Timeframe Text Maintenance tasks or SFG2012 codes.
Facilities/Asset Management Maintenance Required 0 to 300hrs Text Maintenance tasks required during this time frame.
Facilities/Asset Management Maintenance Required 301 to 600hrs Text Maintenance tasks required during this time frame.
Facilities/Asset Management Maintenance Required 601 to 1000hrs Text Maintenance tasks required during this time frame.
Facilities/Asset Management Maintenance Required 1001 to 2000hrs Text Maintenance tasks required during this time frame.
Facilities/Asset Management Maintenance Required 2001 to 4000hrs Text Maintenance tasks required during this time frame.
Facilities/Asset Management Maintenance Required 4001 to 8000hrs Text Maintenance tasks required during this time frame.
Facilities/Asset Management Maintance Required 8001 to 12000hrs Text Maintenance tasks required during this time frame.
Facilities/Asset Management Expected Life Years
Facilities/Asset Management Warranty ID Text
Post Applied Finishes
Facilities/Asset Management Graffiti Resistance Text Post applied graffiti protection
Facilities/Asset Management DDA Requirements Text